RAL Space Large TVAC Suites
RAL Space Large TVAC Suites
22 Nov 2018
Yes
-
Yes
Page Image
Image Caption
Page Content
RAL Space has 2 large TVAC chambers in the R100 complex. Details of these are:
Two Space Test Chambers (STC's) both 5m diameter x 6m length
Temperature range -180°C +120°C
Vacuum rating: 10-7 mbar (payload and temperature dependent)
Dedicated Optical Ground Support Equipment (OGSE) rooms
Direct Electrical Ground Support Equipment (EGSE) access areas
Dry pumping system throughout, with molecular contamination control
Clean Room support facilities
Clean room suites 250 m² each, ISO class 5/6
High-performance vibration isolation both 5m chambers is designed into building:
Optically-sensitive instruments are mounted on a set of ‘quiet’ rails in the chamber, which are directly coupled to a seismic block, isolated from the chamber body
All other equipment coupled to building structure via a set of ‘noisy’ rails mounted on chamber body
Overall seismic mass for each chamber ~300 tonnes resting on 22 air suspension bags
Seismic block extends beyond chamber at both ends enabling OGSE to be coupled to the block and to the quiet rails
Interfaces external to the vacuum chamber are steel plates with grid pattern of holes
5m diameter chamber with one end of the seismic isolation
block in the foreground