Typical STC Cleanroom suite – Optical support equipment
19 Mar 2018
Yes
-  

 

 

 

Yes

​​

 
​Specifications:
  • Validated to ISO14644 for ISO6 particle counts at rest.
  • Monitored in real time for airborne particle counts, temperature, humidity and cascade pressure.
  • 4000K LED lighting with high illumination level
  • ESD safe floors to EN IEC 61340
  • Minimal plastic use to reduce ESD risk
  • Multiple power supply options including UPS and Generator backed up supplies in both single and three phase
  • Dry filtered compressed air
  • Boil off nitrogen gas
  • Vacuum extract system with limited capacity.
  • Oxygen depletion monitoring for safety
  • Blinds on windows for privacy and darkening of room
  • Individually access controlled.
  • Black wall and floor finished to meet the requirements of optical projects.
  • Access controlled with dedicated change room
 

​Test Optical Ground Support (OGSE) cleanroom - SLSTR testing





Contact: