RAL Space Typical STC Cleanroom suite-instrument loading
28 Mar 2018
Yes
-  

 

 

 

No
 
  • Validated to ISO14644 for ISO6 particle counts at rest with ISO5 area covering approx. 25m2 in front of the chamber door
  • Monitored in real time for airborne particle counts, temperature, humidity and cascade pressure.
  • 4000K LED lighting with high illumination level
  • ESD safe floors to EN IEC 61340
  • Minimal plastic use to reduce ESD risk
  • Multiple power supply options including UPS and Generator backed up supplies in both single and three phase
  • Dry filtered compressed air
  • Boil off nitrogen gas
  • Vacuum extract system with limited capacity.
  • 5000kg overhead crane
  • Oxygen depletion monitoring for safety
  • Blinds on windows for privacy and darkening of room
  • Access controlled with dedicated change room​​



Contact: