Edinburgh Vibration Facility
21 Mar 2018
Yes
-  

 

 

 

No

​Edinburgh Vibration Test Facility​​

 

​Manufacturer: Data Physics Vibration Systems 

  • Typical tests: MIL-STD-202G, Method 204D 
    • Test Conditions: A, B, C, D, E, G 
  • Shaker Control Limitations: 
    • Frequency range: 5 to 2000Hz 
    • Max displacement: 50.8mm 
    • Max velocity: 1700mm/s 
    • Max acceleration: 88g 
  • MIL-STD-202G, Method 214A Test Condition I-F (20.71Grms) 
  • MIL-STD-202G, Method 214A Test Condition II-E (19.64Grms) 
  • MIL-STD-202G, Method 213 Table 213-1 
    • Test Conditions A, B, G, H, J or K

The facility was set up specifically for in-house te​​sting and would not normally be available for external customers​
Contact: