Airbus Stevenage Climatic Testing Facility
11 Feb 2020
Yes
-  

 

 

The Airbus Stevenage Environmental Test (EVT) climatic facilities consist of five climatic chambers.

Yes
 
​Each climate chamber is located within the EVT laboratory alongside our Thermal Vacuum facilities. Their varied sizes, temperature capabilities and access ports allow us to cater for a large variety of thermal testing requirements. Four are cryogenic rated and use liquid Nitrogen as a direct cooling method. We also have a humidity controlled chamber which maintains less extreme temperatures. Each of our climatic facilities is fully programmable and automated using advanced Eurotherm Controllers. Combine this with our data logging facilities and the scenarios we can cater for are unlimited.
Tiger - Cryogenic Chamber
  • Internal Dimensions: 600mm3
  • Temperature Range: +180°C / -180°C
  • Max temperature Rate: 10-15°C/min
  • Controller: Eurotherm 2704
Rhino - Large Cryogenic Chamber
  • Internal Dimensions: H= 3600mm W= 4800mm D= 3600mm
  • Temperature Range: +180°C / -160°C
  • Max temperature Rate: 2.5-5°C/min
  • Controller: Eurotherm 2704
Cryo Montford - Cryogenic Chamber
  • Internal Dimensions: H= 600mm W= 900mm D= 600mm
  • Temperature Range: +180°C / -180°C
  • Max temperature Rate: 5-10°C/min
  • Controller: Eurotherm 2704
Fissions - Humidity Chamber
  • Internal Dimensions: 1000mm3
  • Temperature Range: +150°C / -70°C
  • Max temperature Rate: 2°C/min
  • Controller: Eurotherm 2704
Hippo - Cryogenic Chamber
  • Internal Dimensions: 1500mm3
  • Temperature Range: +200°C / -180°C
  • Max temperature Rate: 2.5-5°C/min
  • Controller: Eurotherm 2704

Contact: